Simple digital panel indicator, equipped with measurement input Pt100, Pt500, Pt1000
TECHNICAL DETAILS
Inputs |
temperature Pt100, Pt500, Pt1000, automatic recognition of 2, 3 and 4-conductor connection |
Power consumption |
for 110V AC and 230V AC: max. 1,5 VA; for 24V DC: max. 1 W |
Case material |
NORYL UL94V-0 |
Measurement range |
-100°C ÷ 600°C |
Operating temperature |
0°C ÷ +50°C; -20°C ÷ +50°C (on special request) |
Protection class |
IP 65 (front side when an additional seal is installed); IP 40 (front side); IP 20 (case and connection clips) |
Display |
LED, red, 4 x 13 mm high |
Power supply |
110V AC ± 10%, 230V AC ± 10% or 24V DC (10V ÷ 30V DC), non separated from measurement input |
Accuracy |
0,1% @25°C |
Communication interface |
RS-485, 8N1 and 8N2, 1200 ÷ 115200 bit/s, Modbus RTU |
Stability |
typ. 50 ppm/°C |
Resolution |
0,1°C |
Storage temperature |
-10°C ÷ +70°C; -20°C do +70°C (depending on version) |
Case |
panel mounting |
Case dimensions |
for 24V DC: 72 x 36 x 77 mm; for 230V AC: 72 x 36 x 94 mm |
Panel cut-out dimensions |
67 x 32,5 mm |
Installation depth |
for version 24V DC: min. 78 mm; for 230V AC: min. 95 mm |