Oval gear flow meter Type VO...VA

by SIKA
€0,00
SKU VA
Possible areas of application
SIKA oval gear meters were developed for volume and flow measurement of liquids, and are used in applications including:
  • Lubricant monitoring
  • Food, beverages and tobacco production

Description

  • Positive displacement meter for volumetric flow rate or total flow measurement
  • No inlet or outlet section required
  • High-quality construction for long service life and high reliability
  • Long-term stability
  • High measurement accuracy and repeatability
  • Easy installation

Function
Oval gear meters are displacement-type volume meters that transport defined incremental volumes in individual measuring chambers. The measuring element consists of two high precision toothed oval gears, which are driven by the flow of the medium and mesh with each other. In this way, a defined volume is transported for each rotation of the pair of oval gears. The number of rotations is a measure of the amount of fluid that has passed through the meter. The rotations are detected by a sensor element.

TECHNICAL FEATURES

Measuring range [l/min]

VO 015
VO 06
VO 1
VO 2
VO 5
VO 10
VO 50
VO 115

 

0.1...1
0.5...5
0.1...10
1...30
5...50
10...100
30...300
70...650

Process connection

VO 015
VO 06
VO 1
VO 2
VO 5
VO 10
VO 50
VO 115

 





G 1
G 1
G 2
G 2

Nominal puls rate [1/l]

VO 015
VO 06
VO 1
VO 2
VO 5
VO 10
VO 50
VO 115

 

3100
333
166
100
40
20
4
1,7

Accuracy*

±0.5 % of reading

Repeatability*

< 0.05 %

Pressure rating

Up to 40 bar (up to 25 bar with FEP seal)

Temperature range

Standard
High temperature sensor

 

-10...70 °C
-40...125 °C

Allowable Viscosity

0.3...350 mPa s

Degree of protection EN 60529

IP67

 DOWNLOAD