The magnetic-inductive induQ® flow sensors of the VMM series are thanks to their robust design suitable for use in harsher ambient conditions. The steel fitting is fully welded and therefore very stable and insensitive to interference.
The magnetic-inductive flow sensor type VMM200 is for example used in applications such as
- Water and wastewater
- Mining, cement and minerals
- Pulp and paper industry
- Steel industry
- Energy industry and supply utilities
- Agriculture
Function
The smart flow sensors of the induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes.
Regarding flow proportional output signals two versions are available:
- Frequency output signal (standard)
- Analog and frequency output signal (option)
The pulse rate can be configured at the factory.
TECHNICAL FEATURES
Available in both separate and compact design |
|
Nominal diameter |
DN 200 |
Flow range Flow velocity range [m/s] |
0.25...10 |
Process connection |
Process connection Flange connection in accordance with EN 1092-1 or |
Accuracy* v = 1...10 m/s additionally Frequency output |
±0.5 % of reading
±0.05 % per 10 K |
Repeatability |
±0.15 % of reading |
Medium / min. conductivity of medium |
Water and other conductive liquids / 50 μS/cm |
Medium temperature Hard rubber |
0...90 °C |
Ambient temperature Hard rubber |
0...80 °C |
Compressive strength EN1092-1 |
PN 10 |
Frequency output Pulse rate (factory-set) [1/m³] |
250 |
Analogue output Operating range |
0...20 mA / 4 ... 20 mA, selectable |
Alarm output Quantity |
2 |
Power supply |
230 VAC -15 % / +10 %, 50/60 Hz |
Electrical connection |
Electrical connection Plug connector M20 x 1.5 |
Degree of protection |
IP67 |